With the energy sector facing significant cyber risk, a large renewable energy company wanted to assess the security of its operational technology (OT) infrastructure across a network of 30 solar farms. A comprehensive OT assessment by Kroll identified serious security risks, including visibility gaps, weak monitoring and underutilized security controls, and resulted in an actionable roadmap to mitigate them, significantly advancing the company’s long-term resilience in an increasingly complex threat landscape.

Overview

 

Industry
  • Renewable energy
 
Challenges
  • Limited OT Infrastructure visibility
  • Sector under increasing attack

 

 

Kroll Services
  • OT security assessment
 
Impact
  • Accelerated insight into architectural and configurational weaknesses and security vulnerabilities 
  • Enhanced asset and network visibility
  • Actionable remediation roadmap
  • Enhanced operational resilience

The Challenge

A leading renewable energy operator with more than 30 solar farms in North America needed to ensure its OT infrastructure was robust enough to withstand the rise in cyber threats facing the energy sector. The organization had made several sound OT infrastructure design choices. Each farm’s network was isolated from the others, reducing the risk of a single compromise cascading across multiple sites. These farms were unmanned and standalone, with no direct corporate IT connection into the OT network, limiting enterprise-to-OT attack paths. A further strength was that remote employees and vendor staff used a privileged access solution rather than a traditional VPN, with benefits including certificate–based authentication instead of passwords, authentication logging and session recording for accountability and just-enough access connectivity restricted to specific target systems, not broad networks.

Despite these strong security foundations, the organization lacked a comprehensive understanding of its OT security posture. There was no centralized inventory OT assets or consistent visibility into the firmware and patch levels, configurations and known vulnerabilities. While individual solar farms were isolated from corporate IT and from one another, limited visibility into asset communications and operational dependencies within each site made it difficult to gain assurance over their security posture. This included ensuring vulnerabilities were identified and managed, appropriate compensating controls were in place where remediation was not feasible, asset lifecycles were effectively managed and emerging threats could be detected and responded to in a timely manner.

Kroll’s Solution

Kroll’s highly skilled OT experts led a comprehensive engagement that combined OT security architecture review, risk assessment and hands-on technical validation. The Kroll Team worked with the client’s engineering, operations and security stakeholders to understand the architecture and existing controls, review available documentation and configurations, assess the risk related to assets, connectivity and remote access, and monitor and validate findings against the live environment. As part of the assessment, Kroll deployed industrial intrusion detection systems (IDS) at a representative sample of farms to analyze network traffic, identify connected assets and their communication pattern, and detect potential security threats. This provided valuable technical evidence to complement the broader architecture and risk assessment, helping validate existing controls and identify security gaps that were not apparent from documentation and stakeholder interviews alone.

The assessment uncovered serious weaknesses that aligned with the issues Kroll frequently observes across the energy, manufacturing and utilities sectors. Limited asset and network visibility remains one of the most persistent OT security challenges in this sector—a finding reflected in Kroll’s fieldwork and wider industry studies.

These issues included:

Visibility Gaps - The company had no centralized inventory or telemetry which meant that operators could not easily identify all devices, their patch levels or configurations. Communication patterns between critical assets such as Real-Time Automation Controllers (RTACs), inverters and MET stations were undocumented, making segmentation/tiered zoning difficult. Although the farms were segregated from corporate IT and other sites, limited visibility into internal communication flows made it difficult to assess opportunities for further zone-banded segmentation. Understanding which assets communicate, the protocols they use and their operational dependencies would help establish appropriate security zones and restrict unnecessary connectivity between critical control systems and wider OT systems to reduce lateral movement opportunities.

Weak Monitoring - Without OT-specific deep-packet inspection, protocol-aware analysis or behavioral baselining, the security operations center had limited visibility into suspicious activity within industrial networks, including potential lateral movement, unauthorized control commands and unexpected changes in device behavior.

Under-Leveraged Controls - Strong technologies for access control existed, but they weren’t integrated into incident response or monitoring workflows, limiting their effectiveness.

SSH Exposed to the Internet - Another important finding came when an industrial intrusion detection system (IDS) was deployed. Within hours it flagged repeated connection attempts from known malicious IP addresses scanning for open services. In this case, the OT environment had SSH exposed to the internet. Bots were actively attempting to establish connections. Fortunately, SSH was configured to use certificate-based authentication rather than passwords, so the brute-force attempts failed. But the exposure still represented unnecessary risk. Restricting SSH access to approved source IP addresses or routing through a controlled remote access gateway, would have significantly reduced unnecessary internet exposure. This observation underlined a critical point: Adversaries are always probing for entry points and attempting to exploit weak gates. Even when strong authentication is in place, unnecessary exposure expands the attack surface and creates opportunities for compromise.

Overall, the assessment identified that the operator was running critical renewable energy assets with some sound design foundations, but without the visibility and monitoring needed to assure resilience. This meant that while remote access was well controlled, the day-to-day state of assets and their interconnections, as well as their exposure to the outside world, remained opaque.

Kroll kept the company updated at every stage of the assessment and delivered a report on the results, setting out the steps required to mitigate the issues identified. This structured roadmap enabled the company to take fast and decisive action, while minimizing operational disruption and wider organizational risk.

Impact

Comprehensive Risk Visibility

Kroll’s OT security assessment uncovered critical weaknesses in the company’s OT infrastructure that were leaving it vulnerable to significant threats. As a result of this insight, the company is now able to recognize and address the organizational blind spots that left it vulnerable to attack.

Strategic OT Risk Roadmap

As part of the OT security assessment, Kroll delivered tailored, actionable guidance that translated technical findings into business risks and defensible, measurable recommendations, accelerating the company’s implementation of enhanced access controls, segmentation and policy alignment to strengthen security and mitigate risks.

Cross-Functional Collaboration

Kroll’s seamless approach ensured the highly comprehensive assessment process did not disrupt business operations, while ensuring that operational teams such as facilities management, cybersecurity leadership and executive stakeholders were kept fully updated at each stage of the process.

Enhanced Organizational Resilience

By identifying previously unrecognized exposures and establishing a prioritized improvement roadmap, Kroll helped the organization make more informed decisions about strengthening the security and resilience of its renewable energy operations. 